Homes that arrive as a system.
Structural insulated panels with magnesium-oxide skins, machined in a factory and locked together on site. A shell that goes up in days, holds its line in a storm, and stays dry in salt air.
- 01
- Interlock panels
- 02
- 200+ mph engineering
- 03
- One-week shell
What a structural insulated panel actually is.
A structural insulated panel — a SIP — is a sandwich. Two strong facings are bonded to a rigid insulative core, and the assembly behaves like a steel I-beam: the facings act as flanges in tension and compression, while the core acts as the web that keeps them apart and resists buckling.
Because there are no studs, there are no repeated thermal bridges. Because it is made in a factory, the panel is square, consistent and dry before it reaches the site. And because the facings are magnesium oxide board rather than oriented strand board, the panel does not feed mould, does not burn like timber, and does not depend on formaldehyde glues.
Magnesium oxide is not a substitute for timber. It is a different class of material.
MgO is inorganic. It does not provide the fuel load that timber framing does, and fire resistance is measured in hours rather than minutes.
The board resists water damage and does not swell, delaminate or rot the way OSB and plywood do.
Mould needs organic material to grow on. A mineral skin removes the substrate, which matters in a humid marine climate.
No formaldehyde-based binders, and no off-gassing of the kind associated with resin-bonded wood composites.
Higher compressive and impact strength than plywood, OSB or particleboard of comparable thickness.
Undercoat and top coat go straight onto the board. Available in wood and stone finishes where specified.
The joint is the engineering.
Most prefabricated systems fail at the connections, not the panels. The interlock method puts the connection inside the system: a profiled spline aligns each module, and a cam-lock draws the joint closed and keeps it closed.
Every panel is a load path. Because the modules are locked into a continuous shell rather than nailed to studs at intervals, lateral loads from wind and seismic movement distribute across the whole envelope instead of concentrating at fasteners.
Two workers can set a wall module in under five minutes, including a pre-fitted door or window. That is what makes a one-week lockable shell realistic on a site with a small crew.
- 3×
- Lateral load capacity
- 5 min
- Per wall module
- 1 week
- To a lockable shell
Built for the hurricane belt, not adapted to it.
The panel system is engineered for wind loads in excess of 200 mph, with a flat roof profile that reduces the aerofoil lift that peels conventional roofs off in a storm.
Engineered for wind loads in excess of 200 mph, with uplift-resistant roof and interlock detailing.
Up to three times the lateral load capacity of a conventionally framed wall, resisting racking forces.
Panels have passed large-missile impact testing of the kind required in high-wind building codes.
A flat profile avoids the aerofoil effect that generates uplift on pitched roofs during a hurricane.
A monolithic envelope distributes racking forces rather than concentrating them at joints.
No site-cut gaps in the envelope, which removes the internal pressure build-up that lifts roofs.

Hurricane Charley, Florida, August 2004
A panel-built home in the path of Charley came through with two cracked impact windows and some damaged vinyl siding. Conventionally constructed homes in the same neighbourhood were devastated.
In a separate event, a tornado with documented winds over 200 mph damaged 80 homes. The panel-built home in its path recorded only two cracked impact windows and damage to the vinyl siding.
From a level base to a lockable shell in a week.
The programme is short because the components arrive finished. Site work is assembly, not fabrication.

- 01
Base
The foundation or levelled base is set out and verified. Everything above depends on this plane.
- 02
Floor
FRP I-beam joists are laid to engineering, topped with a waterproof panel subfloor.
- 03
Walls
Wall modules are lifted, interlocked and cam-locked. Doors and windows arrive pre-fitted.
- 04
Roof
Roof panels are set and the flat roof is waterproofed and detailed for uplift resistance.
- 05
Services
Electrical and plumbing first fix run through the panel voids and service zones.
- 06
Envelope
External cladding, internal linings, joinery and finishes close the house in.
- 07
Handover
Kitchen and bathroom modules, snagging, commissioning and keys.
What arrives in a kit.
A kit is a building system, not a pile of materials. The list below reflects a standard configuration; final inclusions are fixed at order.
- Foundation system or base specification
- Interlock SIP wall modules
- FRP I-beam floor joists and panel subfloor
- Roof panels and waterproofing
- Internal wall panels
- External cladding — ACP, WPC or coloured steel
- Windows and external doors, pre-fitted
- Flat roof edge and rainwater detailing
- Sealants and flashings
- Electrical first and second fix
- Plumbing and sanitaryware
- Kitchen and bathroom modules
- Internal linings and paint specification
- Solar PV and battery storage
- Solar-driven air conditioning
- Premium cladding and finishes
- Extended covered verandah
From a single-room cottage to four storeys.
Modules are sized for container freight and lifted into place. Areas shown are indicative and vary with configuration.
Single-volume cottage for a single occupant or short-stay use.
The core family home. Two bedrooms, open living, covered entry.
Larger family configuration with a separate kitchen and utility zone.
Modules stack and lift into place for buildings up to four storeys.
A documentation pathway, not a promise.
Every project is delivered against the building code of Antigua and Barbuda, with structural calculations, product certification and installation manuals issued as a package for review.
The panel system carries third-party test data for wind, impact and fire performance. Where a local authority requires additional verification, we commission project-specific engineering rather than relying on generic certification.
- Engineered plans and structural calculations per project
- Third-party test reports for wind, impact and fire
- Installation manuals and QA checklists for the build crew
- Local authority submission support
- As-built documentation at handover
- 01 · Panel engineeringStructural insulated panel engineering data for MgO-skinned interlock systems, including wind, lateral load and impact testing.
- 02 · Charley case studyHurricane Charley, Florida, August 2004 — documentary case study supplied with the reference material.
- 03 · Barbuda 2017BBC News and UNDP reporting on Hurricane Irma, September 2017: an estimated 95% of structures on Barbuda damaged or destroyed; the entire population evacuated.
Design your first home.
Tell us the site, the household and the budget. We will come back with a typology, a kit scope and an indicative programme.